Kirloskar 20 kVA - 160 kVA

Prime Rating at rated rpm ( as per ISO8528)1

kVA

40

   

62.5

   

100

125

 

kW

32

   

50

   

80

100

 

Genset Model

KG1-40AS

   

KG1-62.5AS

   

KG1-100WS

KG1-125WS

 

Frequency

Hz

50

   

50

   

50

50

 

Power factor

lagging

0.8

   

0.8

   

0.8

0.8

 

Voltage

V

230 (1Ø) & 415 (3Ø)

 

Governing class (As per ISO 8528 Part-V)

 

G2

   

G2

   

G3

G3

 

Noise level

dBA

< 75

   

< 75

   

< 75

< 75

 

Fuel Consumption* 

At 100% Load

Ltrs/hr 

9.9

   

16.2

   

21.9

27.4

 

At 75% Load

7.9

   

12.7

   

16.9

20.2

 

At 50% Load

5.8

   

8.9

   

12.2

15.3

 

Fuel tank capacity

Ltrs

100

   

150

   

230

230

 

Weight of genset with canopy (approx..)^

Dry

Kg

1270

   

1700

   

2040

2090

 

Wet

Kg

1370

   

1825

   

2240

2290

 

Overall dimensions of genset^

Length

mm

2400

   

3150

   

3220

3220

 

Width

mm

1050

   

1200

   

1300

1300

 

Height

mm

1670

   

1635

   

1795

1795

 

Electrical Battery starting voltage 

Volts-DC

12

   

12

   

12

12

 

ENGINE

Engine Model

 

HA494TCI G1

   

HA694TCI G1

   

4K1080TA G2

4K1080TA G2

 

Rated output (Prime Continuous rating as per ISO 8528-1)

KW

41.19

   

61

   

114.7

114.7

 

HP

56

   

83

   

156

156

 

No. of cylinder

Number

4

   

6

   

4

4

 

Cubic capacity

Ltrs

3.77

   

5.65

   

4.32

4.32

 

Bore x Stroke

mm

100 x 120

   

105 x 120

   

105 x 120

105 x 125

 

Rated Speed

RPM

1500

   

1500

   

1500

1500

 

Aspiration

NA/TC/TA

TC

   

TC

   

TA

TA

 

Lube Oil change period

Hrs

500

   

500

   

500

500

 

Lube Oil Sump Capacity

Ltrs

8.3

   

11

   

14

14

 

Coolant Capacity

Ltrs

   

   

21

21

 

ALTERNATOR

Insulation Class

 

Class H

Alternator Efficiency (at 100% load) 0.8 pf**

%

89.2

   

91

   

92

92.5

 

Max Voltage Dip at Full Load 0.8 pf Lag

Sec

< 20%

   

< 20%

   

< 20%

< 20%

 

Max Time to build up rated voltage at Rated RPM

< 5 sec provided engine reach the rated speed

 

For Intermediate ratings, Kindly contact nearest KOEL office

For intermediate ratings, kindly contact nearest KOEL office

Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )

** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
** For Site Conditions other than standard operating conditions consult KOEL for available prime power.

<< Back to Product List