Kirloskar diesel genset air cooled
15 kVA - 62.5 kVA


Prime Rating at rated rpm ( as per ISO8528)1

kVA

15

 

25

30

40

 

62.5

 

kW

12

 

20

24

32

 

50

 

Genset Model

 

KG1-15AS

 

KG1-25AS

KG1-30AS

KG1-40AS

 

KG1-62.5AS

 

Frequency

Hz

50

 

50

50

50

 

50

 

Power factor

lagging

0.8

 

0.8

0.8

0.8

 

0.8

 

Voltage

V

230 (1Ø ) & 415  (3Ø) 

Governing class ( As per ISO 8528 Part-V)

 

G2

 

G2

G2

G2

 

G2

 

Noise level

dBA

< 75

 

< 75

< 75

< 75

 

< 75

 

 

Fuel Consumption*

At 100 % Load

Ltrs/Hr

4

 

6.4

8.2

9.9

 

16.2

 

At 75 % Load

3

 

5

6.4

7.9

 

12.7

 

At 50 % Load

2.2

 

4

4.9

5.8

 

8.9

 

Fuel Tank Capacity

Ltrs

65

 

65

65

100

 

150

 

Overall dimensions of genset (L x W x H)^

mm

1740 x
1050 x
1410

 

2130 x
1050 x
1520

1130 x
1180 x
2130

2400 x
1050 x
1670

 

3150 x
1200 x
1635

 

Dry weight of genset with canopy (approx..)^

Kg

900

 

1050

1050

1270

 

1700

 

Wet weight of genset with canopy (approx..)^

Kg

950

 

1100

1520

1370

 

1825

 

Electrical Battery starting voltage 

Volts-DC

12

 

12

12

12

 

12

 

ENGINE

Engine Model

HA294 G1

 

HA394 TCI G1

HA394 TCI G2

HA494TCI G1

 

HA694TCI G1

 

Rated output (Prime Continuous rating as per ISO 8528-1)

kW

15.1

 

23.5

29.4

41.19

 

61

 

HP

20.5

 

32

40

56

 

83

 

No. of cylinder 

Number

2

 

3

3

4

 

6

 

Cubic capacity 2

Ltrs

1.88

 

2.89

2.89

3.77

 

5.65

 

Bore x Stroke

mm

100 x 120

 

100 x 120

100 x 120

100 x 120

 

100 x 120

 

Rated Speed

RPM

1500

 

1500

1500

1500

 

1500

 

Aspiration

NA/TC/TA

NA

 

TC

TC

TC

 

TC

 

Lube Oil change period

hrs.

500

 

500

500

500

 

500

 

Lube oil Sump Capacity

Ltrs

5

 

8

8

8.3

 

11

 

Coolant Capacity

Ltrs

NA

 

NA

NA

 

 

 

 

ALTERNATOR

Insulation Class

 

Class H

Alternator Efficiency (at 100% load) 0.8 pf**

%

86

 

88.8

88.8

89.2

 

91

 

Max Voltage Dip at Full Load 0.8 pf Lag

sec

 < 20 %

 

 < 16 %

 < 16 %

 < 16 %

 

 < 20 %

 

Max Time to build up rated voltage at Rated RPM

< 5 sec provided engine reach the rated speed

For intermediate ratings, kindly contact nearest KOEL office

Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )

** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
** For Site Conditions other than standard operating conditions consult KOEL for available prime power.

<< Back to Product List